OPERATION
Auto Mode
Level Transducer Control Startup
NOTE: Attempting to navigate away from the Auto Mode screen while the pump is in operation will cause a
warning screen to appear. Refer to
4
3
NOTE: Float switch(es) on/off status is indicated by the illustration on the screen, but does not accu-
rately portray installation depths.
1.
If not already complete, set up and configure the transducer and its application.
Refer to
"Transducer Application Setup" on page 17
on page
18.
2. Return to Auto Mode screen.
3. Press Level Setpoint and enter the desired level to maintain.
Press ENT to enter and close.
4. Choose the Units for display.
5. For applications with a backup float, press Set Backup Float Speed (Hz) to enter the desired speed to run the
pump in the event the backup float is triggered.
Refer to
"Backup Float Fault" on page
6. Press ENABLE button.
NOTE: When the current level is within bounds for a run command, the pump will start.
7.
Monitor rotation of the motor fan and shaft coupling.
8. If rotation is incorrect, press FWD/REV and confirm the selection in the pop-up dialog box.
The pump will slow to a stop, change direction, and restart automatically.
NOTE: Speed will be adjusted automatically to maintain the selected level.
9. Press DISABLE to turn off the pump and deactivate auto mode.