Status
Meaning
Indicates the end (in minutes) of the current
TIMER 1
operating phase.
Indicates the end (in seconds) of the current
TIMER 2
operating phase.
In the event of an alarm, it indicates the time (in
ALARM DELAY
seconds) after which the alarm appears on the
display.
T.MOTHER-
Indicates the temperature measured by the
BOARD
sensor inside the control unit.
Indicates the status of the brazier cleaner (OFF
G.A.S.
= Contact OPEN = Brazier not aligned; ON =
Contact CLOSED = Brazier aligned)
Indicates the status of the level sensor for pellets
in the tank (OFF = Sensor covered = Pellets in
PELLET LEV.
the tank above the reserve limit; ON = Sensor
(*)
exposed = Pellets in the tank below the reserve
limit)
Indicates the hours remaining before servicing,
to be requested from the Technical Assistance
SERVICE
Centre
At the expiry of the hours, "SERVICE EXPIRY" will
appear on the display.
(*) If present.
WI-FI STATUS
By selecting the RESET/WPS field within the WI-FI STATUS menu, it
is possible to link the Wi-Fi module to the Internet network via WPS
or disconnect it from the Internet network to which it was previously
connected.
USER SETTINGS
a
WARNING: menu dedicated to expert users only. Ac-
cess by inexpert users can cause serious damage to
the appliance, objects and the environment, as well
as personal injuries. The manufacturer declines all
responsibility deriving from improper calibration of
these values.
The USER SETTINGS menu allows the user to make a limited calibra-
tion of the pellet load (TYPE PELLET) and of the flue gas extractor
speed (TYPE CHIMNEY) according to the procedures indicated in the
following table.
Menu
Meaning
By increasing the value by a single
unit, the pellet load is increased
by about 2%.
TYPE PELLET
By reducing the value by a single
unit, the pellet load is reduced by
about 2%.
By increasing the value by a
single unit, the flue gas extractor
speed (and therefore the flow of
combustion air) is increased by
about 3%.
TYPE CHIMNEY
By reducing the value by a
single unit, the flue gas extractor
speed (and therefore the flow of
combustion air) is reduced by
about 3%.
26
TECHNICAL SETTINGS
a
WARNING: menu reserved for the Technical Assis-
tance Centre. Access by unauthorised personnel
can cause serious damage to the appliance, objects
and the environment, as well as personal injuries.
The manufacturer declines all responsibility deriving
from improper calibration of these values.
RELAX FUNCTION
The RELAX FUNCTION menu is not available.
SET ROOM DUCT
l
The SET ROOM DUCT. Menu is only displayed on
specific models.
The SET ROOM DUCT. Menu allows for accessing and modifying the
room temperature in zone 1 and zone 2, managed by their respective
fans.
The menu is only displayed if the ducted rooms are managed with a
room sensor; in this case, it is advisable to request the aid of the Tech-
nical Assistance Centre to enable the necessary parameters.
The image below shows the screen inside the SET ROOM DUCT. pa-
rameter, namely the room temperature set-point relative to zone 1.
The
or
s
parameter among "SET ROOM 1" or "SET ROOM 2".
The
or
+
-
temperature to between 7°C and 40°C.
Press the
O
Settable
values
-9÷+9
-9÷+9
COMMISSIONING AND USE
SET ROOM DUCT.
SET ROOM 1
20°
button can be used to select the SET ROOM DUCT.
E
button can be used to modify the value of the selected
button to exit the menu saving the set value.
CS.SB80.IST_EN_Rev. 2.0_09-23