SERVICING
Adjust the floor-mounted feet (A) to level the
appliance .
WARNING: Those authorised to carry
out the connection operation must have ex-
perience acquired and certified in the specif-
ic sector, in accordance with current legisla-
tion in the appliance's installation country .
The connection must make to the proper
standards and must comply with all the rel-
evant regulations and legislation .
To make the connection, connect the mains
line to the appliance's connection pipe, fitting a
shut-off tap (A), to allow the water supply to be
cut off when necessary .
Easily accessible filters must be fitted down-
stream of the tap .
Parameters to be checked
Pressure
pH
TDS
Hardness
Langelier index ( Recommended) (**)
Salt and metallic ion content
Requested
Recommended (**)
(**) Valori differenti da questi parametri possono causare corrosioni se combinati con un uso e ambiente sbagliati.
3413950_inst_GB
LEVELLING
WATER CONNECTION
WARNING: The appliance must be
supplied with drinking water having the
characteristics shown in the table .
Chlorine
Chlorides
Sulphates
Iron
Copper
Manganese
A
A
Value
200÷400 kPa (2÷4 bar)
7÷8 .5
40÷150 ppm
3÷9°f (1,5÷5°d, 2 .1÷6 .3°e, 30÷90
ppm)
>0 .5
<0,1 mg/l
<10 mg/l
<30 mg/l
<0,1 mg/l
<0,05 mg/l
<0,05 mg/l