ADJUSTMENTS
To carry out this operation, proceed as follows .
Remove the handle (B) .
1)
Undo the screws (C) and remove the control
2)
panel (D) .
Undo the nut (E) .
3)
Turn the screw (F):
4)
– clockwise to block gas and movement in ad-
vance .
– anticlockwise to delay blocking gas and
movement .
Raise and lower the tank to ensure that the
5)
adjustment is correct; the tank must be level .
If not, repeat point 4 .
Tighten nut (E) holding screw (F) still .
6)
Replace the control panel (D) and the knob
7)
(B) on completion of the operation .
Switch on the appliance and check that it op-
8)
erates correctly (the temperature light must
be on) .
To carry out this operation, proceed as follows .
Fit the spanner (A) onto the hexagon (B) .
1)
Keep a firm grip on the spanner (A) and undo
2)
the locking screw (C) .
Turn the key (A) clockwise to load the spring
3)
or anticlockwise to unload it (on the left side)
and anticlockwise to load or clockwise to un-
load it (right side) .
C
B
A
3413950_inst_GB
ADJUSTING THE WELL MICROSWITCH
ADJUSTING THE LID COUNTER-BALANCING
B
C
Salita
F
Once the correct balance is obtained, screw
4)
in the screws (C) without tightening them
fully .
Use the spanner (A) to turn the shaft until it
5)
is located in one of the seats provided .
Fully tighten the screws (C) .
6)
ENGLISH
D
C
G
E
C
B
A
15