SERVICING
NOTE: The appliance is supplied at an
operating voltage 400V/3N (indicated on
the sticker applied to the dataplate); con-
version to 230V/3 can be carried out as de-
scribed below .
HAZARD: Before doing any work, cut
off the mains electricity supply .
Remove the handle (C) .
1)
Undo the screws (D) and remove the control
2)
panel (E) .
Undo the screws (F) to remove the lid (G) .
3)
Fit the jumper (H) to make the electrical con-
4)
nection of the terminals (L-M) .
Change the connections to the motor termi-
5)
nal board (N) as shown in the figure .
Fit the lid (G) and secure it with the screw (F) .
6)
Replace the control panel (E) and the knob
7)
(C) on completion of the operation .
Remove the test voltage indicator sticker
8)
from the dataplate and apply the new one to
identify the voltage being used .
NOTE: On completion of the operation
make sure that there are no malfunctions .
3413950_inst_GB
CONVERSION OF ELECTRICITY SUPPLY
C
D
N
N
ENGLISH
E
D
F
G
M
H
L
13