Product Expeller (Fig. 4); Vending A Product; Adjusting The Thermostat Temperature - FAS BABY Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

14
7.3

PRODUCT EXPELLER (FIG. 4)

The expeller -B- can be used when there are products in sacks like chips or others. The expeller will
help them coming out of the spiral. It is hooked up at the end of the spiral and acts as an additional part of
the product to vend pushing it out of the tray.
7.4

VENDING A PRODUCT

After loading the machine, setting the selling prices for each product, positioning the price labels,
checking that the trays have been turned in selling position, the machine is ready to vend.
1) Insert enough money to buy the product.
2) Dial on the panel the combination corresponding to the chosen product.
3) Take the product from the delivery door.
E
N
G
7.5

ADJUSTING THE THERMOSTAT TEMPERATURE

L
General information
I
The digital thermostat controls A FIG. 5 the activity of the compressor and the defrosting cycles (by forceably
S
stopping the compressor). It is powered with a voltage of 230 V.
H
The probe is connected to a terminal of the mains voltage; use only probes with double insulation type NTC.
When replacing the probe, use only original spare parts.
In normal conditions of use, the instrument displays the temperature detected by the cell probe: by pressing
the UP key for at least 4 seconds, the instrument requests a defrosting cycle; if an alarm is active, the
instrument displays the alarm code until its cause has been removed (see section Signals and Alarms)
Programming the working setpoint
Press the SET key to display the current working setpoint value: the "comp" led flashes rapidly. To modify
the value, keep the SET key pressed down and at the same time operate on the UP or DOWN keys (the
working set point can be set between the established limits of min. 8°C and max. 16 °C); having modified
the value, the SET key must be the last to be released.
Signals and alarms
Signals:
The "comp" led is lit
The "comp" led is flashing
Alarms:
The display shows the message "E0"
The display shows the message "E2"
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
The electronic thermostat installed produces a delay of 3 minutes in the
activation of the refrigeration unit.
Indicates that the output is activated
A defrosting cycle is in progress
Indicates one of the following faults: the type of cell probe is not
correct, the cell probe is defective, incorrect cell probe-instrument
connection, the temperature detected by the cell probe is outside
the admissable limits of the cell probe (the output is deactivated).
Indicates corruption of the configuration data: switch the instrument
off and on again; if the alarm does not disappear when the
machine is turned back on, it will be necessary to replace the
instrument (the output is deactivated).
FIG. 5
BABY FAS – Issue 04

Publicidad

Tabla de contenido
loading

Tabla de contenido