5.10 Cooling Time
The cooling time as given in the fitting manufacturer's
instructions has to be respected. If the bar code provided
by the fitting manufacturer contains cooling time data,
it will be displayed at the end of the welding process and
will be counted down to zero. This countdown can be ac-
knowledged and canceled at any time by the STOP/RESET
key. However, note that for that time the pipe fitting joint
which is still warm must not be subjected to an external
force. No cooling time is displayed if the fitting code does
not contain any such information.
5.11 Returning to the Start of Parameter Input
After welding is finished, disconnecting the welded fitting
from the unit or pressing the STOP/RESET key will reset the
unit back to the start of entering the welding parameters.
5.12 Using ViewWeld to Manage Logged Welding
Reports, Print Tags, and Assign Geo-data
The ViewWeld feature offers viewing an abstracted ver-
sion of the welding reports recorded during the welding
processes and printing it as a label tag to be affixed to the
joint on the optionally available tag printer. The ViewWeld
abstract shows the report number, the date and time of
the welding and the welding parameters along with an
evaluation of the quality of the joint/welding operation
(see Display 6), where the first displayed abstract is that
of the last performed welding operation.
To call the ViewWeld abstract of a welding report, press the
ñ key in the bar code input screen (see Display 2). Brows-
ing through the saved welding reports is then possible by
pressing the ï or ð cursor keys. To print a tag of the weld-
ing operation of which the abstract is currently displayed,
the label tag printer has to be connected to the welder.
Then press the START/SET key in the ViewWeld screen.
The printed label tag has a QR code (two-dimensional
bar code), in which information identifying the joint is
encoded: date and time, report number, welding system
used, and joint status.
ViewWeld also enables assigning the geo-data of a joint
after it was made, in case they were not recorded with
enabled geo-data logging at the welding operation (see
Sect. 6.7). To do this, call the ViewWeld screen and, if
Version January 2018
HÜRNER HST 300 Pricon 2.0 User's Manual
0015
24.02.13 09:33
M/B
MON HST
315
0058s
025.0V
1.57Ω
Welding OK
Display 6
EN
13