Descargar Imprimir esta página

HURNER HST 300 Pricon 2.0 Manual De Instrucciones página 53

Ocultar thumbs Ver también para HST 300 Pricon 2.0:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
value at start, in any other case the upper limit depends
on the load value and is calculated as the current at start
plus 15%.
11.2.8 Emergency Off
The welding process has been interrupted by pressing the
STOP/RESET key.
11.2.9 Heater Coil Error
The dynamic current value during welding differs by more
than 15% from the required value, indicating a short-circuit
in the heater coil.
11.2.10 Power Supply Failure at Last Welding
The last welding is incomplete. The welding unit was dis-
connected from the power supply voltage while it was
in progress. To go on using the unit, this error has to be
acknowledged by pressing the STOP/RESET key (see also
Sect. 9.4).
12 Technical Specifications
Nominal Voltage
Frequency
Power
Ingress Protection
Primary Current
Ambient Temperature
Output Voltage
Max. Output Current
Memory for Reports
Data Interface Port
(see also the information on the data ports in Sect. 8)
Tolerances:
Temperature
Voltage
Current
Resistance
Operating Range
Version January 2018
230 V
50 Hz / 60 Hz
2800 VA, 80% duty cy.
IP 54
max. 16 A
– 20°C to + 60 °C (– 4°F to + 140°F)
5 V - 48 V
130 A
20,000 welding reports
USB v 2.0 (480 mbit/s)
± 5 %
± 2 %
± 2 %
± 5 %
20 through 1600 mm
HÜRNER HST 300 Pricon 2.0 User's Manual
27
EN

Publicidad