"Check Code Expiry on" means that the welder identifica-
tion code has to be current and not expired (default
period of validity 2 years from code issuance), or the
welding operation cannot be started, "off," that the
validity of the code is not checked at all.
"Memory Control on" means that when the system
memory is full of reports, the unit will be blocked until
the reports are printed or downloaded, "off," that it
works but that the oldest report will be overwritten.
"Manual Input on" means that the manual input of weld-
ing parameters (see Sect. 7) is possible, "off," that the
manual input is not allowed.
"Welder Code Options – M – " means that by pressing the
MENU key, the user can access a sub-menu that allows
determining when the welder code, if it is enabled at
"Recording," has to be entered:always, i. e. before evey
single welding operation, only before the first welding
operation after switching the unit on or only after the
first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting the display
and report language (see Sect. 10.1.1).
"Date/Time – M – " means that by pressing the MENU key,
the user can access a sub-menu for setting the clock
(see Sect. 10.1.2).
"Buzzer Volume – M – " means that by pressing the MENU
key, the user can access a sub-menu for setting the
volume of the status buzzer (see Sect. 10.1.3).
"Temperature Unit – M – " means that by pressing the
MENU key, the user can access a sub-menu for select-
ing centigrade or Fahrenheit as the unit for the tem-
perature.
"Inventory Number – M – " means that by pressing the
MENU key, the user can access a sub-menu for entering
the number under which the unit is inventorized with
the operating company.
"Number of Tags – M – " means that by pressing the
MENU key, the user can access a sub-menu for entering
the number of tags that are printed automatically after
welding with the optional label tag printer if such a
printer is connected.
10.1.1 Selecting the Display Language
When the "Select Language" sub-menu was selected, the
screen changes and the display reproduced in Display 22
appears.
Use the arrow keys ñ and ò to select one of the options,
"Deutsch," "English," and "Français" and confirmby press-
ing the START/SET key.
22
EN
HÜRNER HST 300 Pricon 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
***
SET-UP MENU ***
Manual Input
Wldr Code Option-M-
>Language
***
SET-UP MENU ***
Date/Time
Buzzer Volume
>Temp. Unit
***
SET-UP MENU ***
>Temp. Unit
Inventory No.
Number of Tags
***** LANGUAGE *****
>Deutsch
English
Francais
Version January 2018
-M-
-M-
Display 19
-M-
-M-
-M-
Display 20
-M-
-M-
-M-
Display 21
Display 22