11.1.7 Temperature Error
The ambient temperature measured is outside the operat-
ing range of the welding unit, i.e., below – 20°C (– 4°F) or
over + 60°C (+ 140°F).
11.1.8 Temperatur Sensor Defective
The ambient temperature sensor on the welding cable is
damaged or defective.
11.1.9 Clock Error
The internal system clock works improperly or is defective.
Reset it, or send the welding unit to the manufacturer for
check and service.
11.1.10 Unit to Service
The recommended next service date for the welding unit is
overdue. The service due message has to be acknowledged
by pressing the START/SET key. Send the welding unit to
the manufacturer or an approved service point for service
and check-up.
11.1.11 Input Error
A code that was entered is incorrect. At manual welding
parameter input, no welding time was entered. An incor-
rect value was selected in the date setting.
11.1.12 Memory Full
The system memory is full of welding reports. Print or
download the reports in memory or switch memory control
off. Without memory control, a new report overwrites the
oldest existing one.
11.1.13 Download Cancelled
During data transfer or printing, an error condition oc-
curred which could not be cleared.
11.1.14 GPS Module Not Ready
The minute that you have to wait from switching the GPS
module on to the actual recording of the geo-data is not
over yet.