"Geo-data on" means that the geographic coodinates
have to be recorded after every welding (see Sect. 6.7
for details), "off," that this is not possible.
"Installing Company on" means that the company that
performs the installation work has to be entered before
every welding, "off," that this is not possible.
"Print Tags – M – " means that by pressing the MENU key,
the user can access a sub-menu for starting to print (a)
label(s) with reference to a given welding operation,
with the optional label tag printer.
All data can also be read from a bar code with the
scanner, provided such a bar code is available.
Info
11
Self-Monitoring Functions Overview
11.1 Errors During Data Input
11.1.1 Code Error
An erroneous input has occurred, a code tag is poor or has
an error in code symbology or code reading was improper.
11.1.2 No Contact
There is no properly established electric contact between
the welding unit and the fitting (check push-on terminal
on fitting), or the heater coil is defective.
11.1.3 Low Voltage
The input voltage is below 175 volts. Adjust generator
output voltage.
11.1.4 Overvoltage
The input voltage is over 290 volts. Decrease generator
output voltage.
11.1.5 Overheated
The welding unit temperature is too hot. Let it cool down
for about 1 hour, while making sure to leave it switched
on, so the internal fan runs to help cool it down.
11.1.6 System Error
CAUTION!
The welding unit has to be disconnected immediately from
both the power supply and the fitting. The auto-test has
detected an error in the system. The unit must no longer
24
EN