H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
11.1.15 No GPS Signal
There is no reliable signal from the relevant satellites to
the GPS antenna of the module.
11.1.16 Poor GPS Signal
The signal strength is so weak that no precise position can
be recorded. Repeating the recording is recommended.
11.2 Errors During Welding
All errors that occur while welding is in progress are also
indicated by an audible alarm.
11.2.1 Low Voltage
The input voltage is below 175 volts. If the error condition
persists for longer than 15 seconds, the welding process
will be aborted. If the voltage goes down below 170 volts,
the welding process will abort immediately.
11.2.2 Overvoltage
The input voltage is over 290 volts. If the error condition
persists for longer than 15 seconds, the welding process
will be aborted.
11.2.3 Resistance Error
The resistance value of the connected fitting is out of the
read tolerance.
11.2.4 Frequency Error
The frequency of the input voltage is out of tolerance
(42 Hz - 69 Hz).
11.2.5 Voltage Error
Check generator voltage and current. The output voltage
does not correspond to the value previously read; the weld-
ing unit has to be sent to the manufacturer for check-up.
11.2.6 Low Current
The message is displayed if the there is a momentary cur-
rent failure or if the current decreases by more than 15%
per second for 3 seconds.
11.2.7 Excess Current
The output current value is in excess; possible causes: short-
circuit in the heater coil or the welding cable. During the
start stage the upper abort threshold equals 1.18 times the
26
HÜRNER HST 300 Pricon 2.0 User's Manual
Version January 2018
EN

Publicidad

loading