Battery Connection
To Connect the Inverter to Batteries:
1. Locate the positive (+) red and negative (-) black terminals on the
rear side of the inverter.
2. From the positive and the negative terminal covers, remove the hex
nut, split lock and flat washer.
3. Place the positive ring connector onto the positive inverter
terminal. Place the negative ring connector onto the negative DC
input terminal.
4. Place a flat washer and split lock on top of each ring connector.
Put the positive and negative hex nuts over these and tighten to
create a secure connection and prevent excessive heating at this
connection. Insufficient tightening of the terminals could void your
warranty. See Specifications for recommended cable sizing.
5. Connect the red positive (+) wire to the positive (+) connector on
your battery system and connect the black negative (-) wire to the
negative (-) connector on your battery system. It is recommended
that the positive connection should have a UL-rated ANL fuse and
fuse block (see Recommend Cabling and Fusing table) installed
a minimum of 7 inches or maximum of 18 inches from the battery
system's positive connector for battery system protection.
6. Connect Ground: Using the ground wire, directly connect the Main
Ground Lug to the vehicle's chassis or earth ground. See Feature
Identification to locate the Main Ground Screw. All installations
must comply with national and local codes and ordinances.