Troubleshooting/Maintenance
Condition
LCD Display
Overload
Over-
Temperature
LED
Audible
Status
Alarm
Explanation
Green: On
Yes
Loads up to
Red: On
100% run
continuously;
101%-120% for
1 minute; 120-
200% for 0.5
seconds.
If the load
demand from
the equipment
or device
being operated
exceeds the time
intervals listed,
the inverter will
sound an alarm
and shut down
the inverter
output.
Green: On
Yes
The thermal
Red: On
resistor exceeds
176° F (80° C).
24
Solution
Reduce load,
wait 3-5 minutes,
restart the
inverter by power-
cycling the ON/
OFF switch on the
unit or remote
(if equipped).
Alternatively,
reduce the load
and wait 4-6
minutes. The
inverter will
auto-recover
and resume
operation.
Allow the inverter
to cool. Do not
block the cooling
slots or airflow
over and through
the inverter.
The inverter will
automatically
resume operation
after internal
temperature goes
down to 140°F
+/- 41°F (60°C
+/- 5°C).