CEBORA S.p.A.
5.5 - Secondary winding board (32) code 5602210
5.5.1 - Topographical drawing.
- Connector table.
5.5.2
Connector
Terminals
CN1
1(+) - 3(-)
CN1
2
CN1
4(+) - 5(-)
CN1
6
CN2
1 - 2
-
L1 - L2
-
S2 - S1
-
S2 - S3
-
S5 - S4
-
S5 - S6
-
"-"
-
"+"
-
F1
3302342
Function
13.8 Vdc power input for power source output current transducer.
power source output current signal output.
25 Vdc power input for pilot arc/transferred arc switching relay.
pilot arc/transferred arc signal output from reed RL2.
connection to secondary winding rectifier charge resistances
connection for output current levelling inductance (23).
power transformer secondary winding 1 connection (52).
power transformer secondary winding 2 connection (52).
power transformer secondary winding 3 connection (52).
power transformer secondary winding 4 connection (52).
- output for secondary winding board (65) (electrode potential).
+ output for secondary winding board (65) (potential of workpiece to be cut, earth).
+ output for secondary winding board (65) (nozzle potential).