2
INSTALLATION
The boiler must be installed in a fixed loca-
tion and only by specialized and quali-
f i e d f i r m s i n c o m p l i a n c e w i t h a l l
instructions contained in this manual.
Furthermore, the installation must be
in accordance with current standards
and regulations.
2. 1
INSTALLATION
As well as being installed outdoors, the
boilers can be installed indoors without
location and air intake restrictions.
A series of sealed boiler kits are envi-
sioned for installation in closed places
(C type).
2.3
ASSEMBLY TEMPLATE
Follow the instructions given below to
assembly the supplied template correctly
(fig. 4):
– Fix the sheet steel connection element
to the plate (A) and lower plaque (B).
– When the template has been comple-
ted, fix the plate (A) onto the wall using
the two support screws for the boiler.
– Check that the plaque (B) is perfectly
level using a spirit-level, in a way to
obtain the exact positioning and refe-
rence for laying the water and gas
pipes.
– Connect the cocks, supplied in a kit with
the boiler, to the system piping.
2.4
ACCESSORIES SUPPLIED
A cock kit is supplied to make boiler con-
nection to the system easier.
A protection cover is also supplied for
the same, which must be fixed to the
lower face of the boiler and to the wall.
For mounting the cocks kit and protec-
tion, see fig. 4/a.
2.5
CONNECTING UP SYSTEM
To protect the heat system from dama-
ging corrosion, incrustation or deposits,
before installation it is extremely impor-
tant to clean the system using suitable
products such as, for example, Sentinel
X300, X400 or Fernox Cleaner F3.
Complete instructions are provided with
the products but, for further information,
you may dir ectl y cont act SENTINEL
PERFORMANCE SOLUTIONS LTD or FER-
NOX COOKSON ELECTRONICS.
For long-term protection agains corro-
sion and deposits, the use of inhibitors
such as Sentinel X100 or Fernox Protec-
tor F1 is recommended after cleaning
the system. It is important to check the
64
1/2"
3/4"
1/2"
ATTENTION: After having made the connections, mount the
non-connected resistance in the position indicated in the figure.
Fig. 4
3/4"
3/4"
Fig. 4/a