TEMPERATURES DISPLAY
BOILER
It is possible to display the temperatures
detected instantaneously by the central
heating probes (SM) and domestic hot
water probes (SS).
TELEPHONE ACTIVATOR
See connection layout in figure 11. The func-
tionality requested of the telephone activa-
tor is "potential free contact". Using the
telephone activator (not supplied) it is pos-
sible to remote control a transaction:
INITIAL PARAMETERS AND RE-MEMORISATION PROCEDURE
After pressing the key (reset), see point "TO ENABLE RE-MEMORISATION" in paragraph "LANGUAGE/DATE/TIME REGULATION"; the fac-
tory parameters are reset, which are the same for both the winter and the between season programmes:
SET: min = 6
T1 = 16 °C
T2 = 18 °C
T3 = 21 °C
manual = 21 °C
LANGUAGE = Italian
TIME = 0 - 24
NOTE: To change the value set
for a level, see paragraph
"PROGRAMMING"
DISCONNECTION OF REMOTE CONTROL
The sanitary and antifreeze functions are guaranteed in any case, even if the remote control is disconnected.
To display the value of the central heating
probe SM, press the (S) and (HEAT) but-
tons at the same time.
[HEAT]: escape temperature display
mode.
- AUTOMATIC MODE
- OFF MODE
PROG: WINTER
from MONDAY to SUNDAY
PROG: BETWEEN SEASON
To display the value of the domestic hot
water probe SS, press the (S) and
(DHW) buttons at the same time.
[DHW]: escape temperature display
mode.
: sequence
1 second
CLOSE
: sequence
1 second
00:00 - 06:00
06:00 - 09:00
09:00 - 12:00
12:00 - 15:00
15:00 - 18:00
18:00 - 22:00
22:00 - 24:00
from MONDAY to SUNDAY
CLOSE
1 second
OPEN
OPEN
1 second
From - to
Level
Value
T1
16 °C
T3
21 °C
T2
18° C
T3
21 °C
T2
18°C
T3
21°C
T1
16 °C
Fig. 33
85