Descargar Imprimir esta página

GE Profile PFDS450 Manual Del Propietario E Instalación página 25

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Instructions
EXHAUSTING THE DRYER
WARNING
-
To reduce the risk of fire
or personal injury:
, This clothes dryer must be exhausted to the outdoors.
, Use only 4" rigid metal ducting for the home exhaust
duct.
, Use only 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-type) duct to connect
the dryer
to the home exhaust
duct. It must
be installed
in accordance
with
the
instructions
found
in
"Connecting the Dryer to House Vent" on page 26 of
this manual.
, Do not terminate
exhaust
in a chimney, a wall,
a ceiling, gas vent, crawl space, attic, under an
enclosed floor, or in any other concealed
space
of a building. The accumulated
lint could cause a
potential fire hazard.
, Never terminate
the exhaust into a common
duct
with a kitchen exhaust system. A combination
of
grease and lint creates a potential fire hazard.
, Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate
lint,
creating a potential fire hazard.
, Never install a screen in or over the exhaust duct. This
will cause lint to accumulate, creating a potential fire
hazard.
, Do not assemble
ductwork
with
any fasteners
that extend
into the duct. These fasteners
can
accumulate lint, creating a potential fire hazard.
, Do not obstruct incoming or exhausted air.
, Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once a year.
, This dryer comes ready for rear exhausting. If space
is limited, use the instructions
on pages 29-31 to
exhaust directly from the sides or bottom
of the
cabinet.
EXHAUST SYSTEM CHECKLIST
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry
of birds or other wildlife.
• Termination
should present minimal resistance to
the exhaust airflow and should require little or no
maintenance to prevent clogging.
• Never install a screen in or over the exhaust duct.
• Wall caps must be installed at least 12" above ground
level or any other obstruction with the opening pointed
down.
SEPARATIONOF TURNS
Forbest performance, separate all turns by at least/4
ft. of straight duct, includingdistancebetween lastturn
and dampenedwall cap.
SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end of
each section of duct must point away from the dryer.
• Do not assemble the ductwork with fasteners that
extend into the duct. They will serve as a collection
point for lint.
• Duct joints should be made air- and moisture-tight
by wrapping the overlapped joints with duct tape or
aluminum tape.
• Horizontal
runs should slope down
towards
the
outdoors 1/4" per foot.
INSULATION
Ductwork that runs through an unheated area or is
near air conditioning should be insulated to reduce
condensation and lint buildup.
TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT
17 Phillips-head screwdriver
C1Duct tape or duct
clamp
17 Rigid or UL-listed
flexible metal 4" (10.2
cm) duct
17 Drill with 1/8" drill bit
(for bottom venting)
17 Hacksaw
C1Vent hood