9. Installing the holders ... (Optional accessory)
The holders help keep longer workpieces stable and
in place during the cutting operation.
(1) As indicated in Fig. 23, use a steel square for aligning
the upper edge of the holders with the base surface.
Loosen the 6 mm wing nut. Turn a height adjustment
bolt 6 mm, and adjust the height of the holder.
(2) After adjustment, firmly tighten the wing nut and
fasten the holder with the 6 mm wing knob (optional
accessory). If the length of Height Adjustment Bolt
6 mm is insufficient, spread a thin plate beneath.
Make sure the end of Height Adjustment Bolt 6 mm
does not protrude from the holder. (Fig. 23)
Holder
(Optional accessory)
Steel square
6 mm wing nut
(Optional
Height adjustment bolt 6 mm
accessory)
(Optional accessory)
10. Stopper for precision cutting ... (Stopper and holder
are optional accessory)
The stopper facilitates continuous precision cutting in
lengths of 11 in. to 17-3/4 in. (280 mm to 450 mm).
To install the stopper, attach it to the holder with the
6 mm wing bolt as shown in Fig. 24.
Stopper
(Optional accessory)
Workpiece
Move
6 mm wing bolt
(Optional accessory)
26
6 mm knob bolt
(Optional accessory)
Base surface
Fig. 23
Holder
(Optional accessory)
6 mm wing nut
(Optional
accessory)
Height adjustment
bolt 6 mm
(Optional accessory)
Fig. 24
11. Slide carriage system
WARNING
To reduce the risk of injury, return slide carriage
to the full rear position after each crosscut
operation.
For chop cutting operations on small workpieces,
slide the cutting head assembly completely toward
the rear of the unit and tighten the slide securing
knob.
To cut wide boards up to 312 mm, the slide securing
knob must be loosened to allow the cutting head slide
freely. (Fig. 25)
Slide securing knob
12. Miter scale adjustment
○ Down the head and insert the locking pin.
Unlock the miter lock handle and swing the turntable
until the positive stop locks it at the 0° miter position.
Do not lock the miter lock handle. Place a square
against the saw's fence and blade, as shown in
Fig. 26 (Do not touch the tips of the blade teeth with
the square.
To do so will cause an inaccurate measurement.)
If the saw blade is not exactly perpendicular to the
fence, loosen the 6 mm machine screws (4 pcs.) that
hold the miter scale and move the miter lock handle
and the scale left or right until the blade is
perpendicular to the fence, as measured with the
square.
Retighten the 6 mm machine screws (4 pcs.).
(Fig. 26) Pay no attention to the reading of the
indicator (for miter scale) at this time.
Fig. 25