Error messages:
Error
Meaning
ERROR 1
The temperature is
too high.
(the temperature
in the housing has
increased to over
75 °C)
ERROR 2
Charge current is
too high
(for 5 seconds, the
charge current is
10% higher than
the set value)
ERROR 3
Residual current
(residual current is
greater than 6 mA
DC or 30 mA AC)
ERROR 4
Self test failed
ERROR 5
Under voltage
(input voltage below
180 V for 5 sec.)
ERROR 6
Over voltage
(input voltage is
over 275 V for
5 sec.)
ERROR 7
Internal component
fault
(relay)
Solution
Disconnect the device from the car and
mains. Wait until the housing tempera-
ture has dropped, then start the charging
process again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again. If the error should occur again,
return the charger
repair.
Disconnect the device from the car and
mains. Wait until the mains voltage rises
to over 190 V. Then start the charging
process again.
Disconnect the device from the car and
mains. Wait until the mains voltage
drops to below 265 V. Then start the
charging process again.
Disconnect the device from the car and
mains. Return the charger
dealer for repair.
to the dealer for
1
to the
1
GB/IE/NI/CY/MT