ERROR 8
The temperature in
the electric car
connection cable
is too high
(over 80 °C).
ERROR 9
CP voltage is
incorrect
ERROR 10
Short circuit cables
(CP to PE)
ERROR 11
Relay contact error
ERROR 12
Charge current is
too high
(for 1.5 seconds,
the charge current
is 100% higher
than the set value)
ERROR 13
PE Test failed
ERROR 14
RS485 Master error Only one device may be set as the
ERROR 15
RS485 Slave error.
Connection with
Master charger lost
ERROR 16
RS485 address
error
z Cleaning
Attention: The device must
not be submerged in water.
There is a risk of injury due
to electric shock if moisture
enters the device.
22
GB/IE/NI/CY/MT
Disconnect the device from the car and
mains. Wait until the temperature in the
electric car connection cable
7
fallen. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Disconnect the device from the car and
mains. Then start the charging process
again.
Check protective conductor and PE
cable
Master.
Check RS485 cables and make sure,
that the Master charger is switched on.
Check settings. It is possible that the
PCB will need to be replaced.
Do not use cleaners or solvents.
These could damage the device
beyond repair.
Keep the housing and device
accessories clean.
Use a damp cloth or a soft brush
to clean the device and the
accessories.
has
7