Result 2 / 3
The specified tightening torque of the fastener was exceeded.
▶ Back off the fastener and set the torque module to a lower stage.
▶ Tighten the fastener with the new stage setting and repeat this test step.
Result 3 / 3
The fastener was tightened to the specified tightening torque.
This stage setting is correct for this fastener.
6.4.4
"Not controlled" operating mode
In this operating mode the torque module is deactivated. The torque module therefore does not have to
be actually removed when it is not needed for a short period of use. The impact wrench works as though
the torque module were not installed. The torque indicator of the impact wrench shows the selected torque
stage and the setting can be changed by means of the torque selector button.
Display icons in the "Not controlled" operating mode:
6.5
Setting the operating mode
There are 2 ways of setting the operating mode to suit the type of fastener.
6.5.1
Setting operating mode by scanning barcode, QR code or data matrix code
If a barcode, QR code or data matrix code is available for the Hilti product to be tightened, the operating
mode can be set correctly for the product quickly and easily by scanning the code.
1. Unlock the torque module. → page 26
2. Press the "Scan" button.
▶ The scanner is activated and the
is ready.
3. Now hold the module approximately 15 centimeters (6") away, with the projected cross-hairs centered
on the barcode, QR code or data matrix code.
Result 1 / 2
The LEDs show green.
The display shows
The confirmation tone sounds.
The operating mode for the fastener to be tightened appears on the display.
Result 2 / 2
Parameters for the fastener to be tightened might not yet be available in the torque module's
memory.
Hilti has separate SI­AT-specific operating instructions for the SI­AT-compatible
fasteners. Printed on these operating instructions you will find a QR code that you can scan
with the torque module in order to load the parameters into the torque module's memory.
The operating parameters for the product to be tightened can also be uploaded to the torque
module via USB with the AT Documentation Software. Regularly check the currency of the
software and parameter versions installed in the torque module in order to ensure that the latest
parameters are always applied.
The LEDs flash red.
appears on the display (code could not be read or was not recognized).
The warning tone sounds.
▶ Press the "Scan" button and scan the code again.
4. If the fastener is Tracefast-capable, select whether you want to use the Tracefast operating mode (
not (
).
5. Lock the torque module. → page 26
▶ If the Tracefast operating mode was activated,
▶ If the Tracefast operating mode was deactivated,
6.5.2
Setting the operating mode with the control panel buttons
If no barcode, QR code or data matrix code is available for the fastener to be tightened, the operating mode
can be set manually by means of the buttons on the torque module.