Malfunction
The message indicating
"Power consumption too
high" is displayed.
The message indicating "But-
ton cell empty" is displayed.
The message indicating "Ser-
vice impact wrench immedi-
ately" is displayed.
The message indicating
"Hardware fault" is displayed.
The message indicating
"Documentation function
deactivated" is displayed.
The message indicating "Da-
ta memory almost full" is
displayed. (This message
appears when the value is
≥ 90 %.)
The message indicating "Data
memory completely full" is
displayed.
*2343813*
Possible cause
Current input is briefly too high.
The button cell battery for the
clock in the torque module is
discharged.
Maintenance of the impact wrench
must be carried out immediately.
A device error has been detected.
Documentation function deactivat-
ed (warning only).
Data memory in the torque mod-
ule is almost full. Note: When data
memory is completely full, the old-
est data will be overwritten!
Data memory in the torque module
is completely full. Note: The oldest
data will be overwritten!
2343813
Action to be taken
▶ Press the OK button to confirm
the message.
▶ Repeat the tightening operation.
▶ Contact Hilti Service if the
message reappears.
The correctness of the date and
time in the documentation report
can no longer be guaranteed.
▶ Contact Hilti Service and have
the battery changed.
The "Adaptive", "Tracefast" and
"Tightening" operating modes can
no longer be selected.
▶ Contact Hilti Service to have
maintenance of the impact
wrench carried out.
▶ Connect the torque module to a
PC.
▶ Use the
AT Documentation Software
program to read the fault
memory and follow the trou-
bleshooting instructions issued
by the program.
▶ If you need the documentation
function, connect the torque
module to the PC and activate
the documentation function in
the
AT Documentation Software
program.
▶ If necessary, press the OK
button to hide the message and
continue the starting process
for the torque module.
▶ Connect the torque module to a
PC.
▶ Use the
AT Documentation Software
program to export the data to a
report.
▶ Then delete the data from the
torque module's memory to free
up storage space.
▶ Connect the torque module to a
PC.
▶ Use the
AT Documentation Software
program to export the data to a
report.
▶ Then delete the data from the
torque module's memory to free
up storage space.