en
150 | MT ZERO 6 Touch | Maintenance
4. Close the wheel guard.
The measurement will start. Wait until the pro-
cess is completed.
After the start, the laser beam will be activated.
i
Some machine versions require the wheel to be
positioned manually according to the instructions
shown on the monitor.
i
During the calibration of the device, the laser beam
will be directed at the holes in the calibration plate.
5. Lift the wheel guard fully.
6. Release the quick-clamping ring to be able to turn
the calibration plate.
Fig. 137: Releasing the clamping ring
i
Once the shaft rotates, the laser will be deactivated.
If necessary, reposition the shaft by hand.
7. Turn the calibration plate, and hold it in place when
it is centered across from the shaft until the beam
intersects with the holes.
Fig. 138: Laser beam being emitted
|
1 695 600 965
2020-02-27
8. Use a quick-clamping ring to lock the calibration
plate in such a way that it is centered across from
the shaft.
!
Once the beam intersects with all the holes, the
calibration will be complete. If it does not, adjust
the position of the accessories in the places
pictured and make sure the position of the laser
beam is correct.
Fig. 139: Adjusting an external laser
"
Calibration complete.
9. Remove the quick-clamping ring an the calibration
plate.
10. Install the cover of the sonar probe.
Pneumatic version
1. Push the pedal up.
The tie rod will move to the right.
2. Remove any dirt with a wire brush.
3. Place the calibration plate included in the scope of
delivery against the flange's surface.
4. Insert a small cone to center the calibration plate on
the flange shaft.
5. Slide the spacer plate onto the shaft, and press
it against the plate in such a way that the plate is
centered on the shaft.
Fig. 140: Attaching the calibration plate
12
6
Beissbarth GmbH