22. To store the appliance: The packaging for storage must be resistant
in order to avoid that the appliance may take damage and to avoid
the possible leakage of refrigerant gas.
23. Recovered refrigerant must not be discharged in another refrigerating
system unless it has been cleaned and checked.
24. Dismantling MUST be carried out by a qualified technician whom
MUST use the PPE correctly and MUST perfectly know the equipment.
All the refrigerants MUST be recovered safely; always collect a
sample of oil and refrigerant before emptying the circuit.
25. Before starting any dismantling operation:
- Electrically insulate the system.
- Ensure that you have mechanical handling equipment at your
disposal to handle the tanks, if necessary.
- The equipment and recovery tanks MUST be in compliance with
the standards.
26. The equipment must be labelled indicating that it has been deactivated
and emptied of refrigerant. The label must be dated and signed.
Make sure that on the equipment are present labels indicating that
the equipment contains flammable refrigerant.
27. If the compressors or compressor oils must be removed, it is
necessary to check that they have been extracted safely and at an
acceptable level to ensure that the flammable refrigerant has not
remained inside the lubricant. The evacuation process must be
carried out before returning the compressor to the suppliers. To
speed up this process, only electric heating of the compressor body
must be used.
0.3 - PROPER USE
• The air-conditioner should be used for the exclusive purpose of producing
hot or cool air (on demand) for the sole purpose of obtaining a comfortable
temperature in the room.
• Improper use of the machine (outside and inside units) causing damage to
persons, property or animals relieve OLIMPIA SPLENDID of any liability.
0.4 - HAZARDOUS ZONES
• The climate controllers must not be installed in environments with
the presence of inflammable gases, explosive gases, in very humid
environments (laundries, greenhouses, etc.), or in places with other
machines that generate a strong heat source, in proximity of a sources of
salt water or sulphurous water.
• DO NOT use gas, gasoline or other inflammable liquids near to the climate