INDOOR UNIT INSTALLATION 
Step2: Install Mounting Plate 
2.1
Take the mounting plate from the back of indoor unit. 
2.2 Ensure to meet the minimum installation dimension requirements as step 1, according to the size 
of mounting plate, determine the position and stick the mounting plate close to the wall. 
2.3 Adjust the mounting plate to a horizontal state with a spirit level, then mark out the screw hole 
positions on the wall. 
2.4
Put down the mounting plate and drill holes in the marked positions with drill. 
2.5
Insert expansion rubber plugs into the holes, then hang the mounting plate and fix it with screws. 
Spirit level 
Mounting plate 
Note: 
(I) Make sure the mounting plate is firm enough and flat against the wall after installation.
(II) This figure shown may be different from the actual object, please take the latter as the standard. 
Step3: Drill Wall Holes 
3.1
Three optional piping modes show be determined 
Mode1: Left, the Fresh air pipe, the refrigerant piping ,the drainage pipe, and connecting cables 
all are through one hole to the outside. 
Mode2: Right, the Fresh air pipe, the refrigerant piping ,the drainage pipe, and connecting cables 
all are through one hole to the outside 
Mode3: Back, the Fresh air pipe, the refrigerant piping ,the drainage pipe, and connecting cables 
go through two side‐by‐side wall holes. 
3.2
For Mode3, follow the reference size for mounting plate and hole to determine location. 