INDOOR UNIT INSTALLATION 
Step7: Connecting Fresh Air Pipe and place the filter 
7.1
According to the wall hole position, select the appropriate piping mode. 
Mode1: Left, together with refrigerant piping ,the drainage pipe, and connecting cables. 
Mode2: Right, together with  refrigerant piping ,the drainage pipe, and connecting cables. 
Mode3: Back, the fresh air pipe is not bundled with other pipes. 
7.2
Measure the length of the fresh air pipe assembly. 
In the "1" and "2" modes, if needed, extend the fresh air tube by uniting the extensions and the rigid 
tube. 
For mode 1:Measure the distance between the left bottom corner of the mounting plate and 
the center of the wall hole, the length of the fresh air pipe assembly is equal to the measured 
length plus 650mm. 
Outdoo
For mode 2:Measure the distance between the left bottom corner of the mounting plate and 
the center of the wall hole, the length of the fresh air pipe assembly is equal to the measured 
length. 
For mode 3:The length of the fresh air pipe assembly is 310mm and the exposed length of 
the fresh air pipe is 50mm. 
Indoor 
Unit  fresh  air 
Measured  length  + 
650mm 
Unit  fresh  air 
inlet 
Indoor 
Crop line 
Measured length 
28 
EN - 30
inlet 
Crop line 
Outdoor
 