INDOOR UNIT INSTALLATION 
Step5: Connect Drainage Hose 
5.1
Adjust the drainage hose(if applicable) 
In some model, both sides of the indoor unit are provided with drainage ports, you can choose 
one of them to attache the drainage hose. And plug the unused drain port with the rubber 
attached in one of the ports. 
5.2 Connect the drainage hose to the drainage port, ensure the joint is firm and the sealing 
effect is good. 
5.3
Wrap the joint firmly with teflon tape to ensure no leaks. 
Note: Make sure there is no twists or dents, and the pipes should be placed obliquely 
downward to avoid blockage, to ensure proper drainage. 
Step6: Connect Wiring 
6.1 Choose the right cables size determined by the maximum operating current on the nameplate. 
(Check the cables size refer to section INSTALLATION PRECAUTIONS) 
6.2
Open the front panel of indoor unit. 
6.3
Use a screwdriver, open the electric control box cover, to reveal the terminal block. 
6.4
Unscrew the cable clamp. 
6.5 Insert one end of the cable into the position of control box from the back of the right end of the 
indoor unit. 
6.6 Connect the wires to corresponding terminal according to the wiring diagram on the electric 
control box cover. And make sure that they are well connected. 
6.7
Screw the cable clamp to fasten the cables. 
6.8
Reinstall the electric control box cover and front panel. 
6.9 For some models, the power сables and connection cables are pre‐installed on the machine at the 
factory. 
Drainage ports 
Control box cover 
Wiring diagram 
27
EN - 29
Cable 
clamp 