Steps to repair protection sponge: (see the figure below)
Cut a section of protection sponge longer than the gap, pull open the two ends, insert the protection sponge, and
apply glue to the joint.
[ Caution ]
Tips for repairing insulation layer:
1. The length of the protection sponge for repair (protection sponge used to fill the gap) must be 5–10 cm longer than
the gap.
2. The protection sponge for repair must be cut neatly.
3. Tightly insert the protection sponge for repair into the gap.
4. All the sectional areas and cuts must be glued.
5. Wrap the joints with tape.
6. There is no need to wrap the concealed sections with a binding tie, otherwise the insulation effect will be reduced.
[ Caution ]
When installing the insulation pipe on site, please cut it according to the actual needs. (Either method (a) or (b) is OK.
Method (c) is incorrect. There must be no gap between the insulation pipe and copper pipe.)
(a)
Straight joint
of copper pipe
300mm
Copper pipe
Protection
sponge for repair
500mm
Not connected
(b)
33
Installation
Protection
sponge
(c)
Clearance

Publicidad