Extend the drainage pipe.
① To extend the length of a drainage pipe, you need to purchase an extension drainage hose locally. Make
sure the extension portion of the drainage hose indoors undergoes heat insulation treatment.
Drainage hose of IDU
[ Caution ]
Indoor parts of the drainage pipe shall be insulated to prevent condensation, and protective sleeves should be thicker
than 10mm.
If the pipe is not wholly insulated, be sure to rebind the cut part.
Use glue or buckles to connect the joints and cuts of the thermal insulation pipe, and make sure it is at the top of the
pipe.
After the drainage test shows that there are no leaks, carry out the insulation of the drainage pipe.
3
Lay and insulate pipes.
① Straighten and place the connecting pipes on the floor, and lay the
drainage pipe and various cables (remember to distinguish the two ends
of the cable) around the connecting pipes.
② Measure and adjust the distances of the low-pressure pipe, high-pressure
pipe and various cables based on the mouth of the drainage pipe, and
bind them together with cable ties.
③ Sort the pipes and cables in the following sequence: drainage pipe at the
bottom, connecting pipe in the middle, and power cable at the top.
④ Start wrapping from the drainage pipe and tie a fast knot.
[ Note ]
The number and type of cables may vary from model to model.
Both ends of the cable are different, so make sure the cable end is correct
before binding the pipes.
The binding shall be seamless and neat in appearance.
Drainage hose
Water pipe insulation
Extended portion of the drainage pipe
Insulation casing (purchased locally)
Water outlet pipe of IDU
38
Installation
Cable
Gas pipe
Gas pipe
Heat
insulation
Binding tie
Drainage pipe
Note: If the drainage pipe is wrapped
above the piping, it may cause
poor drainage or backflow of
water.
Liquid pipe
Liquid pipe