Maintenance of Display Panel
1
Follow the steps above to dismantle the panel assembly.
2
First remove the display box cover, then remove the display panel and unplug the cable.
Display box cover
Maintenance of Infrared Human Sensor, Temperature
Sensor, Drain Pump and Water Level Switch
1
Remove the upper and lower louver near the screw hole, loosen the screws, and then remove
the panel frame.
Upper and lower
louvers
2
Take out the infrared human sensor, remove the
connecting cable and repair the sensor.
Display panel
Screw
(five for model 45/56,
and four for other models)
Spring buckle
(six for model 45/56, and
four for other models)
3
(on the capillary tube)
Infrared
human sensor
(optional)
68
Pull the temperature sensor out of the buckle or sleeve,
pull the plug out of the electric control box and repair
the temperature sensor.
T2A
Installation
Panel frame
T2 (on a semicircular tube)
T2B
(on the output tube)
Room temperature sensor
(on the side of the display panel
mounting bracket)