WARNING!
DO NOT use the respirator unless the regulator is connected correctly. A regulator that is not installed correctly can
separate from the facepiece unexpectedly. Return the respirator to an MSA trained or certified repair person to correct the
condition.
Failure to follow this warning can result in serious personal injury or death.
6. Inhale sharply to start the airflow.
WARNING!
If the respirator does not function properly as described in this section, the respirator must be removed from service and
must be checked and corrected for proper operation by an MSA trained or certified repairperson before using.
Failure to follow this warning can result in serious personal injury or death.
3.8
Cold Weather Operation
WARNING!
• Before going into a hazardous environment, make sure there is no water, moisture, or dampness on or in any of the
respirator components. Any moisture on or in the respirator components can freeze and result in a malfunction of the
respirator. Make sure all components operate correctly.
• Before going into a hazardous environment, make sure there is no water or ice on the inner surfaces and
components of the regulator, regulator buttons, and bypass valve. Make sure the buttons and bypass valve operate
correctly.
• Do NOT use a regulator that has water contamination on the inner surfaces or components. Remove the regulator
from service, and dry all surfaces and components fully. Make sure all regulator components are fully dry before
returning the regulator to service.
Failure to follow this warning can result in serious personal injury or death.
• Any water on or in the respirator components can freeze and restrict airflow. To keep moisture from entering the
regulator, keep the regulator in the regulator keeper when it is not in use.
• When the respirator is away from heat, water spray can freeze on the regulator surface. Ice can build up and bind the
side buttons or the bypass valve. Before entering or re-entering a hazardous atmosphere, make sure there is no ice
on the side buttons or bypass valve, and that they operate correctly.
• Periodically make sure there is no ice on the bypass valve.
• When cleaning the respirator, make sure water does not enter the facepiece or regulator.
• Thoroughly dry the facepiece and facepiece mounted regulator after cleaning and disinfecting. Obey the Confidence
Plus® Cleaning Solution instructions.
US
5. Check proper engagement by pulling on the regulator to ensure that the
regulator is securely attached to the facepiece.
PremAire Cadet
3 Donning
15