Descargar Imprimir esta página

MSA PremAire Cadet Manual De Uso página 17

Respirador de suministro de aire
Ocultar thumbs Ver también para PremAire Cadet:

Publicidad

Idiomas disponibles

Idiomas disponibles

4.1.2
Removing Firehawk Regulator - Push-To-Connect
1. Grasp the top of the regulator.
2. Push the side release buttons and pull the regulator out of facepiece.
4.1.3
Removing the G1 Regulator
WARNING!
DO NOT use a G1 Regulator with an Ultra Elite or Advantage 4000 Facepiece.
Failure to follow this warning can result in serious personal injury or death.
1. Grasp the regulator release buttons.
2. Push the release buttons and pull the regulator out of the facepiece.
3. Open the regulator bypass valve or press the purge button (if equipped) to vent system pressure. Close the bypass
valve.
4. Stow the regulator in the regulator keeper when not in use.
US
2. Push the side release buttons and pull the regulator down and out of facepiece.
3. Slide the regulator up the cover rail until the regulator slide button is free of the
cover rail.
PremAire Cadet
4 Doffing
17

Publicidad

loading

Este manual también es adecuado para:

800810800809