Target Presets (PSET)
PSET function gives user ability to configure 10 preset target torque or target angle settings, each with
a minimum (target), maximum (over range) and batch count value. PSETs are stored in non-volatile
memory so that they are retained while power is off.
Note: After adding a Preset (see below), navigate between manual target torque, angle mode and PSET
screen by repeatedly pressing ENTER
UP
/DOWN
Manual Target Torque Screen
00
100.0
FT-LB
Note: Presets with a non-zero batch count are displayed as 01ofXX.
Adding a Torque Preset
1. From target torque screen, select units of measure.
2. Press and hold UNITS
3. ADD PRESET confirmation screen is displayed. Highlight
buttons then press ENTER
PSET.
4. MINIMUM TORQUE is target value at which green progress lights, audible alert and vibrator turn
on. Initial MINIMUM TORQUE value is value from target torque screen. MINIMUM TORQUE can be
set to any value within wrench torque range by pressing UP
target torque value has been set, press ENTER
5. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red
progress lights turn on. Initial MAXIMUM TORQUE value will be MINIMUM TORQUE plus 4%.
Maximum torque value can be set greater than MINIMUM TORQUE value to 10% above wrench
maximum range by pressing UP
ENTER
button.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP
/DOWN
time target torque is reached if a batch count of zero is entered. Mode Count is displayed as 01ofXX
if a non-zero batch count is entered and resets to 01 after batch count completed. Once desired
value has been set, press ENTER
7. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
8. To enter additional torque presets, repeatedly press ENTER
displayed and repeat steps above.
buttons to select additional configured PSETs.
Manual Target Angle Screen
ENTER
button
90°
U
button for 3 seconds.
button.
buttons to increment/decrement batch count. Mode Count increments each
button.
button. While PSET screen is displayed, press
UP/Down buttons
Preset 3 Angle Screen
PSET 03
90°
UP/Down buttons
Preset 1 Torque Screen
00
PSET 01 01
ENTER
button
100.0
UP/Down buttons
Preset 2 Torque Screen
PSET 02
50.0
UP/Down buttons
YES
NO
menu selection returns to main menu without adding a
button.
/DOWN
buttons. Once desired value has been set, press
9
00
ENTER
button
03
ENTER
of
button
FT-LB
00
ENTER
button
FT-LB
menu selection using UP
/DOWN
buttons. Once desired
button until target torque screen is
/DOWN

Publicidad

loading