Note: If wrench is powered up in torque only measurement mode, angle is not zeroed until mode is
changed to angle measurement mode, at which time torque and angle zeroing begins
automatically after 2 seconds. Wrench should be placed on a stable surface with no torque
applied.
Note: Pressing ENTER
select another measurement mode.
Torque Mode
1. Set Target.
Use UP
2. Select Units of Measure.
Repeatedly press UNITS
displayed.
3. Apply TORQUE.
Grasp center of handle, (DO NOT pull on battery end-cap) and slowly apply torque to fastener
until progress lights display green and a ½ second audible alert and handle vibration alerts
user to stop.
4. Release TORQUE.
Note peak TORQUE reading flashing on LCD display for 10 seconds. Pressing
BACKLIGHT
is released. Momentarily press UP
immediately return to target TORQUE screen. Reapplying TORQUE will immediately start
another TORQUE measurement cycle.
5. Recall Peak TORQUE Reading
To recall last peak TORQUE measurement, press and hold BACKLIGHT
approximately 3 seconds. Peak TORQUE will flash for 10 seconds.
Angle Mode
Note: Do not apply torque while torque and angle are zeroing otherwise torque zero offset will be
incorrect and wrench will indicate an angle reading when torque is released. If this occurs, re-
zero wrench by momentarily pressing POWER
surface with no torque applied.
1. Angle Zero
If "ANGLE ZERO REQ" message is displayed, wait 2 seconds for automatic angle zeroing
sequence before applying torque or moving wrench.
2. Set target.
Use UP
3. Apply Torque and Rotate Wrench.
Grasp center of handle, (DO NOT pull on battery end-cap) and slowly apply torque to fastener
and rotate wrench at a moderate consistent speed until progress lights display green and a
½ second audible alert and handle vibration alerts user to stop.
4. Release torque.
Note alternating peak TORQUE and ANGLE readings flashing on LCD display for 10 seconds.
Pressing BACKLIGHT
until button is released. Momentarily press UP
UNITS
U
(ratcheting) before target screen is displayed will continue ANGLE accumulation as wrench
is rotated.
5. Recall Peak ANGLE Reading
To recall last peak ANGLE measurement, press and hold BACKLIGHT
approximately 3 seconds. Peak TORQUE and ANGLE will be displayed alternately for 10
seconds.
button while angle is zeroing will abort zeroing function to allow user to
/DOWN
buttons to change TORQUE target value.
U
button while on target TORQUE screen until desired units are
button while peak torque is flashing will continue to display value until button
/DOWN
buttons to change target ANGLE value.
button while peak angle is flashing will continue to display value
button to immediately return to target ANGLE screen. Reapplying torque
/DOWN
, ENTER
button with wrench setting on a stable
/DOWN
4
or UNITS
U
, ENTER
or
button to
button for
button for