Chapter 6. Machine adjustment and setting up
The following table indicates the sealing time we recommend setting according to the type and thickness of the pouches.
Type of pouch
Smooth for cooking
Smooth for storage
Smooth made of aluminium
Bellow made of aluminium
(it can be packed only with
"sealing counterbar"; optional)
6.3.2. Program for outside vacuum P5
It is the "Outside Vacuum" program to be used for removing air from specific containers that can be closed hermetically
(not supplied with this product).
In this program parameters "vacuum" and "extravacuum" may be set.
Phase 1
Screw on the "outside vacuum" fitting
(not supplied with this product).
Phase 2
Connect this fitting to the container
using the intake pipe.
With cover open, start the program
by pressing the Start (3) button.
Parameter
Vacuum
Min. = 35.0
(values expressed
Max. = 99.9
in %)
Default = 99.9
Extravacuum
Min. = E00
(values expressed
Max. = E60
in seconds)
Default = E00
Gas
Min. = 00.0
(values expressed
Max. = 60.0
in %)
Default = 00.0
Sealing
Min. = 0.5
(values expressed
Max. = 4.0
in seconds)
Default = 1.5
Pouch thickness (µm)
85 – 95
85 – 95
120 – 140
120 – 140
P1
P2
Min. = 35.0
Max. = 99.9
Default = 97.5
Min. = E00
Max. = E60
Default = E00
Min. = 00.0
Max. = 60.0
Default = 00.0
Min. = 0.5
Max. = 04.0
Default = 1.5
Sealing time (seconds)
1.3 – 1.5
1.3 – 1.5
2.0 – 2.5
2.5 – 3.0
Phase 1
Phase 2
P3
Min. = 35.0
Min. = 35.0
Max. = 99.9
Max. = 99.9
Default = 95.0
Default = 35.0
Min. = E00
Min. = E00
Max. = E60
Max. = E60
Default = E00
Default = E00
Min. = 00.0
Min. = 00.0
Max. = 60.0
Max. = 60.0
Default = 00.0
Default = 00.0
Min. = 0.5
Min. = 0.5
Max. = 04.0
Max. = 4.0
Default = 1.5
Default = 1.5
28
EN
P4
P5
(External Vacuum)
Min. = 35.0
Max. = 99.9
Default = 99.9
Min. = E00
Max. = E60
Default = E00