Chapter 6. Machine adjustment and setting up
6.3.3. Special programs t1, t2, t3.
Infusion cycle.
This is the program for marinading/infusion of foodstuffs.
Insert the food with the herb marinade in the pouch and place it in the tank,
Set packaging parameters (vacuum, infusion time, gas, sealing).
Note: set the infusion time (iC1÷iC10) by pressing buttons (6) and (7);
iC1 = 1minute
iC10 = 10 minutes.
To start the cycle:
Open the cover as soon as the display shows (t1).
Compression.
This is the program to soften meat and meat products. This takes place by subjecting the food to several
repetitions of vacuum cycles, in order to soften the fibrous structure.
Insert the food in the pouch and place it in the tank,
Set packaging parameters (vacuum, extravacuum, vacuum cycle repetitions, sealing).
Note: set the number of vacuum cycle repetitions (t.02÷t.15) by pressing buttons (6) and (7);
t.02 = 2 cycles
t.15 = 15 cycles.
To start the cycle:
Open the cover as soon as the display shows (t2).
Liquid time.
This is the program to set the sealing stage of pouches containing liquid products (soups, etc.).
Based on the temperature of the liquid to be packed in the pouch, set the value "Lt" which automatically
programs execution of the seal.
Insert the food in the pouch and place it in the tank,
Set packaging parameters (vacuum, Lt gradient, gas, sealing).
Note: set the "Lt" gradient value by pressing buttons (6) and (7);
Lt.1 = for products with temperature ~ 40÷45°C
Lt.2 = for products with temperature ~ 45÷55°C
Lt.3 = for products with temperature ~ 55÷70°C
Lt.4 = for products with temperature ~ 70÷80°C
Lt.5 = for products with temperature ~ 80÷85°C.
To start the cycle:
Open the cover as soon as the display shows (t3).
Parameter
Vacuum
(values expressed in %)
Extravacuum
(values expressed in seconds)
Brewing time
(values expressed in minutes)
Repetition of vacuum cycles
(values expressed as number)
Temperature gradient
Gas
(values expressed in %)
Sealing
(values expressed in seconds)
close the cover and press the Start button (3).
close the cover and press the Start button (3).
close the cover and press the Start button (3).
t1
Infusion cycle
Min. = 35.0
Max. = 99.9
Default = 99.9
Min. = iC1
Max. = iC10
Default = iC1
Min. = 00.0
Max. = 60.0
Default = 00.0
Min. = 0.0
Max. = 4.0
Default = 1.5
29
t2
Compression
Min. = 35.0
Max. = 99.9
Default = 99.9
Min. = E00
Max. = E60
Default = E00
Min. = t.02
Max. = t.15
Default = t.02
Min. = 0.0
Max. = 4.0
Default = 1.5
EN
t3
Liquid time
Min. = 35.0
Max. = 99.9
Default = 99.9
Min. = Lt.1
Max. = Lt.5
Default = Lt.1
Min. = 00.0
Max. = 60.0
Default = 00.0
Min. = 0.0
Max. = 4.0
Default = 1.5