PRODUCT OPERATION
OPERATING CONDITIONS
• Maximum ambient temperature is 140°F (60°C), with mini-
mum temperature 5°F (-15°C).
• The life of the impeller depends upon the temperature of the
liquid being pumped.
• High and low temperatures can affect impeller life.
PERMITTED FLUIDS
• Only use the pump with specified products, including fresh
and salt water solutions.
• If in doubt about pump material compatibly, consult the
website or a sales representative.
• If in doubt about the use of the pump in a potentially explo-
sive atmosphere, consult the website or a sales representative.
• If corrosive products are pumped, pump life will be prolonged
if pump is flushed with water at the end of each cycle.
INITIAL START-UP AND DUTY CYCLE
• Complete the installation (as per page 2).
• This is a continuously rated pump for recommended duty cycle
of 30 minutes.
• The pump is self-priming to 4ft (1.2 m).
• Intake lines must be air-tight to ensure self-priming.
• Do not run pump dry.
• Priming may take up to 35 seconds, if priming takes longer
than the designated time, check:
• There are no blockages in the suction hose.
• The inlet filter is not blocked.
• The suction pipework is airtight.
• The height you are priming to is 4ft (1.2 m) maximum.
Do not operate any switches with wet hands.
Voltage
Amp Draw
12 Vdc
12
* Length of run is total distance from power source to pump and back to ground. Wire sizes listed are SAE gauge and metric millimetres².
• The data specified in the above table refers to performance
running at the ideal efficiency points on water at 68ºF (20ºC).
with fully charged battery (12.8v).
• The 'MAX AMP DRAW' refers to the pumps running at their
maximum pressure, which is past their recommended duty
point.
For longer installations, fit thicker cables
(reference ISO 10133).
ELECTRICAL SPECIFICATIONS AND MINIMUM WIRE SIZE
Fuse Size
0-10 (0-3)
25
#16 (1.5mm²)
• Never operate a motor which in any way has been manipulat-
ed and lost its full enclose.
WARNING!
The working temperature of the motor may reach a
maximum of approx. 176°F (80°C) (surface tempera-
ture) which may burn your skin.
• Motors can spark and explosion and death can occur, with
incorrect wiring causing injury or death.
STORAGE AND CLEANING
• If any pump unit needs to be removed for storage purposes, it
must be stored in a cool dry location
• Pump units are rated to IP55. It is recommended that the unit
is wiped down after use.
• Liquids must not be allowed to freeze in the pump body, to
winterise your system all water must be drained from the
entire system, including the pump.
TECHNICAL SPECIFICATIONS
Total Head (DIFF)
Feet
Metres
0
7
13
20
26
33
39
Wire size AWG (mm²) per foot (meter) of length*
10-15 (3-4.6)
15-25 (4.6-7-6)
#14 (2.5mm²)
#12 (4mm²)
• The wire length is the total distance from the battery to the
pump and back to the battery. It is recommended to use a
relay to shorten the main leaders.
• If the fuse fails repeatedly, do not fit a heavier fuse or bridge
the fuse terminals with silver paper or metal wire. Failure
to observe this instruction may result in a fire hazard due to
overheating of cables.
• Exceeding recommended pump discharge pressure will
shorten the impeller life.
5
Capacity
US GPM
LPM
0
16
60
2
14.8
56
4
13.2
50
6
11.4
42
8
8.5
32
10
4.7
18
12
1.6
5
25-40 (7.6-12-2)
#10 (6mm²)
Current
AMPS
14
14.5
15
16
17
18
19
40-60 (12.2-18.3)
#8 (10mm²)

Publicidad