Tube size
¼ " (φ 6.35)
3/8 " (φ 9.52)
1/2 " (φ 12)
5/8 " (φ 15.88)
Dedicated distribution device and air conditioning cable
Inverter
type model
capacity
(Btu/h)
Area of the zone
Power
N
supply
I
cable
Connection
N
cable
L o (L)
1
NOTE: this table is for reference only, installation must comply with the requirements
of local laws and regulations.
3.2 Installation of the indoor unit
Step 1. Select the installation site
1.1 Ensure that the installation complies with the minimum installation dimensions
shown in Figure 4 and complies with the minimum and maximum length of the
connection pipe and the maximum change in elevation.
1.2 The air inlet and outlet shall be free of obstructions, ensuring airflow throughout
the room.
1.3 Condensate can be drained easily and safely.
Newton metre
[N X m]
18 – 20
30 – 35
45 – 50
60 – 65
V0393_EVVO
CLIMA 9000
1.5 mm
2
1.5 mm
2
1.5 mm
2
0.75 mm
2
0.75 mm
2
0.75 mm
2
0.75 mm
2
Foot-pound-force
(1 bf-ft)
24.4 – 27.1
40.6 – 47.4
61.0 – 67.7
81.3 – 88.1
V0394_EVVO
CLIMA 12000
1.5 mm
2
1.5 mm
2
1.5 mm
2
0.75 mm
2
0.75 mm
2
0.75 mm
2
0.75 mm
2
EVVO CLIMA 9000/12000/18000/24000
Kilogram-force meter
(kgf-m)
2.4 – 2.7
4.1 – 4.8
6.2 - 6.9
8.2 – 8.9
V0395_EVVO
V0396_EVVO
CLIMA 18000
CLIMA 24000
1.5 mm
2.5 mm
2
1.5 mm
2.5 mm
2
1.5 mm
2.5 mm
2
0.75 mm
0.75 mm
2
0.75 mm
0.75 mm
2
0.75 mm
0.75 mm
2
0.75 mm
0.75 mm
2
ENGLISH
2
2
2
2
2
2
2
93