Mounting socket
EN 61326: class A). In this case, use a probe with coaxial version.
Fig. 5: Mounting in non-metallic vessel
1
Flange
2
Metal sheet
If this is not possible, use short sockets with small diameter.
used. They can, however, increase the upper blocking distance (dead
band). Check if this is relevant for your measurement.
In such cases, always carry out a false signal suppression after
Fig. 6: Mounting socket
vessel top.
1
d
DN25 ... DN150
> DN150 ... DN200
d
4 Mounting
2
Setup procedure".
h
≤ 150 mm ( 5.91")
≤ 100 mm ( 3.94")
15