4 Mounting
Welding work

Measuring range

16
1
Fig. 7: Socket must be installed ush
1
Unfavourable mounting
2
Socket ush - optimum mounting
Before beginning the welding work, remove the electronics module
from the sensor. By doing this, you avoid damage to the electronics
through inductive coupling.
Fig. 8: Mounting of the sensor with in owing medium
The reference plane for the measuring range of the sensors is the
Keep in mind that a min. distance must be maintained below the refer-
ence plane and possibly also at the end of the probe - measurement
in these areas is not possible (dead band). The length of the cable
can be used all the way to the end only when measuring conductive
2