Interfaz de usuario – Configuración del sistema
Imagen 10–58 Example of a calibration in progress
When an error is detected, the message Calibration Error is displayed next to function.
10.17 Electronic Convergence
What can be done?
The convergence patterns can be used to check the convergence alignment of red, green and blue. If there is
a misalignment of at least one 1 pixel, an electronic realignment is possible.
Mechanical realignment of the convergence can only be done by a qualified service technician.
How to display the convergence settings
1.
In the main menu, navigate to Settings → Maintenance → Electronic Convergence.
Imagen 10–59 Maintenance menu, electronic convergence
The Electronic Convergence menu is displayed.
Imagen 10–60 Example of the electronic convergence menu
2.
Select the desired X or Y value for one of the three colors and confirm.
3.
Use the arrow keys to raise or lower the value and confirm.
4.
Confirm all changes by pressing Enter.
148
R5913592ES /03 Njord and HODR