WIKA TR10-L Manual De Instrucciones página 9

Termorresistencia y termopar protección antideflagrante, tipo de protección contra ignición (ex d)
Ocultar thumbs Ver también para TR10-L:

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Safety
2.5 Ex marking
DANGER!
Danger to life from explosion
Non-observance of these instructions and their contents may result in
the loss of explosion protection.
Installation and commissioning of the instrument in accordance with
manufacturer's specifications.
Observe the safety instructions in this chapter and further explosion
protection instructions in these operating instructions.
Observe the information given in the applicable type examination
certificate and the relevant country-specific regulations for installation
and use in hazardous areas (e.g. IEC 60079-14, NEC, CEC).
Version
Without flame path
Thermowell
(minimum wall thickness
1 mm [0.04 in])
With flame path
With thermowell/protection
tube
(minimum wall thickness
1 mm [0.04 in])
With flame path
Without thermowell/protec-
tion tube
Welded threaded
connection
Electrical values
U
= DC 30 V
m
P
= 2 W
m
WIKA operating instructions, models TR10-L, TC10-L, TR10-0, TC10-0 (Ex d)
ATEX
Gas
Dust
II 2G Ex db IIC
II 2D Ex tb IIIC
T6 ... T4 Gb
T85 °C Db IP66
II 2G Ex db IIB +
II 2D Ex tb IIIC
H2 T6 ... T4 Gb
T85 °C Db IP66
II 2G Ex db IIB +
II 2D Ex tb IIIC
H2 T6 ... T4 Gb
T85 °C Db IP66
II 2G Ex db IIC
II 2D Ex tb IIIC
T6 ... T4 Gb
T85 °C Db IP66
IECEx
Gas
Dust
Ex db IIC
Ex tb IIIC T85 °C
T6 ... T4 Gb
Db IP66
Ex db IIB + H2
Ex tb IIIC T85 °C
T6 ... T4 Gb
Db IP66
Ex db IIB + H2
Ex tb IIIC T85 °C
T6 ... T4 Gb
Db IP66
Ex db IIC
Ex tb IIIC T85 °C
T6 ... T4 Gb
Db IP66
EN