Mode Cycle Count
®
TechAngle
mode cycle count feature is used to indicate number of
times wrench has reached target torque in torque measurement
mode or target angle in angle measurement mode.
Torque and Angle Mode Cycle Counting
1. Numerical counter located in top right of target torque or target angle screen will increment after
each torque or angle cycle if applied torque or angle has reached target value.
2. When toggling between torque mode or angle mode using ENTER
numerical counter will reset back to 00. Counter WILL NOT reset when re-zeroing, on menu
entry/exit or power down.
3. Memory icon will turn on indicating at least one torque or angle cycle data has been stored in
memory.
Main Menu
Main menu displays wrench operational information.
1. From target torque or angle screen, press and hold ENTER
2. Use UP
/DOWN
Menu Selections:
EXIT - Exits Main menu and returns to target screen.
LANGUAGE - Displays language selection menu.
SET HEAD LENGTH - Displays wrench head length entry screen.
SHOW DATA - Displays stored torque and angle data.
CLEAR DATA - Clears stored torque and angle data.
CYCLE COUNT - Displays torque/angle cycle count screen.
SETTINGS - Displays advanced settings menu (see Advanced Settings Section).
CONFIGURE - Displays advanced configuration menu (see Advanced Configuration Section).
3. To select the menu language, press the ENTER button while
highlight the desired language and press the ENTER button
100.0
Target Screen
Note: If French, Spanish or German language is selected, decimal mark selection menu is
displayed. Comma or decimal point can be selected. English defaults to decimal point.
4. To exit Main menu and return to target torque or angle screen, press ENTER
menu selection is highlighted.
Setting Head Length
Note: If an adapter or extension is added to wrench, length of adapter/extension being used can be
entered to correct for a different length than head used to calibrate wrench without requiring
re-calibration.
1. To enter a head length, from target torque or angle screen, press and hold ENTER
seconds.
2. With
SET HEAD LENGTH
3. Set Head Length screen is displayed next. Default head length is length of head at calibration. Use
UP
/DOWN
4. Pressing and holding UP
faster. Pressing UP
5. Default units of length is in inches. Press UNITS
buttons to highlight menu selection then press ENTER
ENTER
00
EXIT
button
LANGUAGE
held
SET HEAD LENGTH
FT-LB
SHOW DATA
Main menu
menu selection highlighted, momentarily press ENTER
buttons to increment/decrement head length.
/DOWN
and DOWN
ENGLISH
ENTER
FRANCAIS
button
ESPANOL
DEUTSCH
Language Selection menu
buttons will progressively increment/decrement value
buttons simultaneously will reset head length to zero.
U
button to change to millimeters.
5
180°
M
MEMORY ICON
button or if target is changed,
button for 3 seconds.
button.
LANGUAGE
is highlighted then
button while
01
MODE CYCLE
COUNT
EXIT
button for 3
button.

Publicidad

loading

Este manual también es adecuado para:

Techangle steel atech3fs250Techangle steel atech4rs600