Viewing and Clearing Wrench Cycle Counter
Each time torque or angle target is reached, wrench cycle counter is incremented. Maximum cycle
count is 999999.
1. From target torque or angle screen, press and hold ENTER
2. Highlight
CYCLE COUNT
3. Press ENTER
4. To exit CYCLE COUNT screen without clearing count, press ENTER
selection is highlighted.
5. To reset wrench cycle count to 0, highlight
6.
EXIT
menu selection is automatically highlighted after count is cleared. Press ENTER
return to main menu.
00
100.0
FT-LB
M
Target Screen
Target Presets (PSET)
PSET function gives user ability to configure 10 preset target torque or target angle settings, each with
a minimum (target), maximum (over range) and batch count value. PSETs are stored in non-volatile
memory so that they are retained while power is off.
Adding a Torque Preset
1. From target torque screen, select units of measure.
2. Press and hold UNITS
3. ADD PRESET confirmation screen is displayed. Highlight
buttons then press ENTER
a PSET.
4. MINIMUM TORQUE is target value at which green progress lights, audible alert and vibrator turn
on. Initial MINIMUM TORQUE value is value from target torque screen. MINIMUM TORQUE can
be set to any value within wrench torque range by pressing UP
desired target torque value has been set, press ENTER
5. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which
red progress lights turn on. Initial MAXIMUM TORQUE value will be MINIMUM TORQUE plus 4%.
Maximum torque value can be set greater than MINIMUM TORQUE value to 10% above wrench
maximum range by pressing UP
ENTER
button.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP
/DOWN
time target torque is reached if a batch count of zero is entered. Mode Count decrements if a
non-zero batch count is entered and resets to batch count value when count reaches zero. Once
desired value has been set, press ENTER
7. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
8. To enter additional torque presets, repeatedly press ENTER
is displayed and repeat steps above.
menu selection using UP
button to display COUNT screen.
ENTER
EXIT
button
LANGUAGE
held
SET HEAD LENGTH
SHOW DATA
M
UP/DOWN buttons
SET HEAD LENGTH
SHOW DATA
CLEAR DATA
CYCLE COUNT
M
U
button for 3 seconds.
button.
buttons to increment/decrement batch count. Mode Count increments each
/DOWN
menu selection then press ENTER
CLEAR
COUNT: 12
CLEAR
EXIT
M
UP/DOWN buttons
COUNT: 12
ENTER
button
CLEAR
EXIT
M
NO
menu selection returns to main menu without adding
/DOWN
buttons. Once desired value has been set, press
button.
8
button for 3 seconds.
buttons.
button while
COUNT: 0
ENTER
button
CLEAR
EXIT
M
SET HEAD LENGTH
ENTER
button
SHOW DATA
CLEAR DATA
CYCLE COUNT
M
YES
menu selection using UP
/DOWN
button.
button until target torque screen
EXIT
menu
button.
button to
ENTER button
/DOWN
buttons. Once