27
30A
31
34A
30
28
29
30B
32
33
34B
4-21
Layout
OPTIMIZATION "Optimisation Screen"
Fig. 4-21
27 BALANCING key
-
Accesses the BALANCING screen.
28 OPT/MIN key
– Starts the Optimisation program
29 MINIMISATION key
-
Starts the Minimisation program.
30 OPERATOR key
- Allows the following selections
USER 1 (A) USER 2 (B)
31 CONFIRMATION / CONTINUE key
-
Allows the user to confi rm the action or acquire the
selection and continue.
32 BACK key
-
Allows going back one step during execution of the
program.
33 RESTART OPT/MIN key
-
Allows restarting after the interruption of an optimi-
sation/minimisation cycle.
34A START key (starts the run)
-
Starts the measuring run. Press to start wheel rota-
tion, with the wheel guard down.
34B STOP key
-
Immediately stops a wheel run already started.
......