The Info Menu Item; Measured Values; Lt Status; Grid Status - Fronius Symo Advanced 10.0-3 208-240 Manual De Instrucciones

Inversores para instalaciones fotovoltaicas acopladas a la red
Ocultar thumbs Ver también para Symo Advanced 10.0-3 208-240:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The INFO menu item

Measured values

PV Iso.
Insulation resistance of the photovoltaic system
Ext. lim.
External limitation
U PV 1 / U PV 2*
Real-time DC voltage at the DC input terminals, even if no energy is being fed in by the
inverter (from first or second MPP Tracker)
* MPP Tracker 2 must be activated - ON - via the Basic menu
GVDPR
Grid voltage-dependent power reduction
Fan #1
Percentage value of fan target power

LT Status

The status display of the last error that occurred in the inverter can be shown.
IMPORTANT! STATE 306 (Power low) and STATE 307 (DC low) state codes naturally ap-
pear every morning and evening due to low solar radiation. These state codes at this time
are not the result of a fault.
-
-
-

Grid Status

The last 5 grid errors that occurred can be displayed:
-
-
-
Device Informa-
The device is used to display settings relevant to a grid operator. The displayed values de-
tion
pend on the respective country setup or device-specific inverter settings.
Display range
After pressing the 'Enter' key, the power stage set status and the last error that oc-
curred are displayed
Use the 'Up' and 'Down' keys to scroll through the list
Press the 'Back' key to exit the status and error list
After pressing the "Enter" key, the last 5 grid errors that occurred are displayed
Use the "up" and "down" keys to scroll through the list
Press the "Back" key to exit the grid error display
General / Country-specific setting / MPP Tracker / Grid monitor-
ing / Grid voltage limits / Grid frequency limits / Q-mode / AC
power limit / AC voltage derating / Fault ride through
43

Publicidad

Tabla de contenido
loading

Tabla de contenido