WING NK CONTROL Block diagram
CAUTION! RADARS and PHOTOCELLS! An
inversion of the connection between the
power supply and contact or the power supply
short circuit may blow the FUSE F1A.
F1A
SIGNAL LED
EMR
RAD.1
RAD.2
FOTO
STOP
M/S
19
18
17
16
15
14
13
12
11
10
J7
J4
DL9
electric lock
connection
J9
fi g.7
J6
K3
+ 24 V DC
22
GND
21
+ 24 V DC
20
GND
19
Emergency
18
Radar 1
17
Photocell test output
16
Radar 2
15
Photocell
14
STOP
13
Master/Slave IN
12
Master/Slave OUT
11
Master/Slave COM
10
J7
J4
Master/Slave IN
(11)
Master/Slave OUT
(12)
Master/Slave COM
(10)
MASTER/SLAVE
(use minimum 3 x
0.25 cable)
- 25 -
CAUTION!
The N.C. contacts (terminals 18-Emergency
and 13-Stop) must be jumpered to the earthing
(terminal 19 or 21) when not used. If they are
not, the automation CANNOT OPERATE!
Note: terminal 14-photocell may be N.C. depending
on the corresponding dipswitch setting.
(22)
(21)
(19)
(17)
(22)
(21)
(19)
(15)
1st inp.
ER4N photocell
ER6N photocell
(use minimum 3 x 0.25 cable)
22
21
terminal board
+ 24 V DC
20
GND
RX1
19
RXC
18
RX2
17
+ AL
16
- AL
15
COM
Photocell
14
NC/NO
13
TX1
12
TXC
11
TX2
10
Connections
+
Power supply
-
RADAR 1
contact
+
Power supply
-
RADAR 2
contact
transmitter
terminal board
-
+
1 2
(19)
(20)
receiver
terminal board
-
+
1 2 3 4 5
(14)
(19)
(20)
white
receiver 1
shielding
receiver 2
white
+
(20)
-
(19)
(14)
red
transmitter 1
shielding
transmitter 2
red