Technical Data - Vaillant atmoMAG mini 11-0/0 XZ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9 Technical data

9
Technical data
Gas instantaneous water heater, type B11, B11 BS
• Please tick off the installed appliance type and set gas
type in Table 9.2.
Feature
Gas category
Hot water volume at
Hot temperature selector setting
Warm temperature selector setting
Maximum thermal load (Q
max.
(with reference to thermal value Hi)
Minimum thermal load (Q
min.
Maximum heating power (P
max.
Minimum heating power (P
min.
Modulation range
Maximum water pressure pw
Minimum water pressure pw
Flue gas temperature at maximum heat-
ing power
Flue gas temperature at minimum heat-
ing power
Maximum flue gas mass flow
Minimum flue gas mass flow
Dimensions
Height
Width
Depth (incl. switches)
∅ Flue pipe connection
Weight (approx.)
CE number (PIN)
Table 9.1 Specific technical data of appliance
1) 15 °C, 1013.25 mbar, dry
16
Unit
MAG mini
INT
11-0/0 XZ
ll
2H3B/P,
l
3B/P,
l
3+
l/min.
2.2 - 5.5
l/min.
4 - 11
)
kW
22.1
1)
)
kW
9.3
)
kW
19.2
)
kW
7.7
kW
7.7 - 19.2
bar
13
max.
bar
0.12
min.
°C
160
°C
110
g/s
14.4
g/s
13.3
mm
580
mm
310
mm
243 (256)
mm
110
kg
12
99BP821
Gas value with reference to set
gas type
← (tick as appropriate)
Natural gas G 20
Gas connection value at maximum
heating power
Connection pressure (gas flow
pressure) p
in front of the appli-
w
ance
1)
Burner nozzle
Pilot burner nozzle
Burner pressure at maximum
heating power
Air quantity required for combus-
tion
← (tick as appropriate)
Liquid gas G 30
Gas connection value at maximum
heating power
Connection pressure (gas flow
pressure) p
in front of the appli-
w
ance
1)
Burner nozzle
Pilot burner nozzle
Burner pressure at maximum
heating power
Air quantity required for combus-
tion
← (tick as appropriate)
Liquid gas G 31
Gas connection value at maximum
heating power
Connection pressure (gas flow
pressure) p
in front of the appli-
w
ance
1)
Burner nozzle
Pilot burner nozzle
Burner pressure at maximum
heating power
Air quantity required for combus-
tion
Table 9.2 Gas values with reference to set gas type
1) The nozzle designation corresponds to the bore diameter
multiplied by 100.
Unit
MAG mini
INT
11-0/0 XZ
3
m
/h
2.3
mbar
20
mm
1.18
mm
0.25
mbar
10.9
3
m
/h
23.3
kg/h
1.7
mbar
30
mm
0.72
mm
0.18
mbar
24
3
m
/h
20.3
kg/h
1.7
mbar
30
mm
0.72
mm
0.18
mbar
24
3
m
/h
20.6
Installation manual atmoMAG