Electrical Connections (Only For Version With Electric Motor); Anchoring System - Butler ERGOLOCK.CB Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7102-M004-0_B
GB
Page 35 of 116
ERGOLOCK.CB - AD - ST
Fig. 21
KEY
1 – Bead breaker arm (# 4004401)
2 – Vane (# 4064201)
3 – Screw for bead-breaker arm (# 140925901)
4 – M12 self-locking nut (# 228006)
5 – Flat washer (# 237069)
6 – D. 40 ball knob (# 903090)
7 – Belleville washer (# 253017)
21. Mount the ring (# 0223000) with the two screws
which are already in place in the machine body.
The grease holder ring can be mounted in four
different positions depending on the requirements
of the user.
UPON COMPLETING ASSEMBLY, CHECK ALL
THE MACHINE FUNCTIONS.
9.3
Electrical connections (only for version
with electric motor)
EVEN THE TINIEST PROCE-
DURE ON THE ELECTRICAL
SYSTEM MUST BE CARRIED
OUT BY PROFESSIONALLY
QUALIFIED STAFF .
As envisaged by the regulations in force, the machine
is not equipped with a master circuit-breaker, but is
fitted for connection to the mains by means of a socket/
plug combination.
INSTRUCTION, USE AND
MAINTENANCE MANUAL
The machine is supplied with a power supply lead 3
metres long. A plug meeting the following requirements
must be fitted to this:
• Conformity to IEC 309
• 230/400 Volt – 16A
• 2P + Earth
• IP 44
The machine, at delivery time, works with a monophase
voltage 200 ÷ 265 V - 50/60 Hz.

10.0 ANCHORING SYSTEM

The packed machine is fixed to a pallet by support
feet. These feet are also utilized for fixing the machine
to the floor in the work area. Secure the machine to
ground using the anchoring bolts as indicated in Fig.
22.
The holes in the solid floor must be about 10 cm deep
with a diameter of 8 mm.
The bolts (Fig. 22 pos. 1) must be inserted in the
holes and fully tightened.
VERSION WITH
MONOPHASE MOTOR
Fig. 22
a=595 mm
b=420 mm